| Charging Type |
Mode 3, Level 2 |
| Input Voltage |
Single Phase 240V | Three Phase 415V |
| Output Voltage |
Single Phase 240V | Three Phase 415V |
| Rated Current |
Upto 32A (Single Phase and Three Phase) |
| Input / Output Power Rating |
Single Phase upto 7.4KW and Three Phase upto 22KW |
| Standards |
IEC62196 | IEC 61851-1 |
| Socket or Connector Type |
Type 2 Socket with Shutter | Type 2 Cable with Gun |
| Number of Charging Outlets |
1 |
1 |
2 |
| Output Cable Length |
5m or 10m optional |
| Protection |
Over-current, Over-voltage, Undervoltage, Ground fault including |
| Metering |
In-built Metering |
| Network Connection |
WIFI / 4G / LAN |
| Communication Protocol |
OCPP 1.6J |
| User Authentication |
RFID | Remote Start Feature |
| Indication |
LED Indication |
| Usage |
Outdoor |
Outdoor |
Outdoor |
| Operating Altitude |
2000 mtr |
| Display |
4.3” color LCD Display |
| Mounting Arrangement |
Wall |
- |
Floor |
| Standard Warranty |
12 Months |
| TriCare: EV Chargers |
| Charge plug/Socket |
Type 2 socket (European standard with shutter), Type 1 cable & plug for US
|
| Locking |
Optional socket actuator and lock release module |
| Power rating |
Up to 22 kW |
| Standard compliance |
ISO / IEC 62196, ISO / IEC61851-1 & -22, ISO / IEC15118 ready (Plug’n’Charge), energy management-capable |
| Communication |
| Mobile Network |
2G (GSM, GPRS, EDGE), 3G (UMTS) & 4G (LTE) |
| Encryption |
TLS |
| Protocol |
OCPP 1.5 / 1.6 (with binary option, roaming capable) |
| Functionality |
Authorization, remote-start, configuration, maintenance, monitoring, operating |
| User Interface |
| Status Display |
LED array (green, yellow, blue), LCD Display optional |
| Authorization |
RFID (Mifare Classic, Desfire EV 2 & other 13.56 MHz RFID standards) |
| Metering |
| Integrated Meter |
MID Meter, other smart meters are optional |
| Remote Meter Access |
Remote meter reading S0 & Modbus, meter status visible in backend |
| Safety |
| RCD |
Type A, integrated DC 6mA sensing system for Type B RCD |
| Degree of protection |
IP54 |
| Impact |
IK10 |
| Mounting |
| Housing |
Aluzinc, various colours |
| Dimensions (L x W x H) |
200x 250 x 1050 mm |
| Mounting |
Lamp post, wall and pole for standalone solution |
| Power inlet |
Attached cable, depending on power rating |
| Inputs/outputs and operation |
| USB1 |
USB devices (Ethernet, WLAN, ...) |
| SIM card |
micro-SIM |
| Features (optional) |
| Communication |
Master for Master/Slave communication with up to 250 Slaves (USB, Ethernet, WLAN, RS485) |
| Load management |
Customer specific & dynamic distribution of power resources |
| Energy management |
Yes |
| Automatic release |
Automatic charge plug release in the case of a power blackout |
| Grid connection |
Directly connectable to the grid |
| Configuration & Firmware |
via USB or remote via backend |